Show simple item record

contributor authorNicola Fontana
contributor authorMaurizio Giugni
contributor authorDavide Portolano
date accessioned2017-05-08T22:03:23Z
date available2017-05-08T22:03:23Z
date copyrightMay 2012
date issued2012
identifier other%28asce%29wr%2E1943-5452%2E0000225.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/70037
description abstractDuring the past few years, issues concerning sustainable management of water distribution systems have attracted interest through an integrated policy aimed at reducing leakage through a pressure management strategy. Pressure reducing valves (PRVs) are often used in water networks to prevent the downstream hydraulic grade from exceeding a set value, although they must be adequately located to maximize their effectiveness. In recent years, the application of turbines or pumps operating as turbines (PATs) appeared as an alternative and sustainable solution to control network pressure and produce energy. In the present paper, PRVs and PATs were used within a district in a Naples’ water distribution network and showed large potential revenues and an attractive capital payback period.
publisherAmerican Society of Civil Engineers
titleLosses Reduction and Energy Production in Water-Distribution Networks
typeJournal Paper
journal volume138
journal issue3
journal titleJournal of Water Resources Planning and Management
identifier doi10.1061/(ASCE)WR.1943-5452.0000179
treeJournal of Water Resources Planning and Management:;2012:;Volume ( 138 ):;issue: 003