Show simple item record

contributor authorRonny Purba
contributor authorMichel Bruneau
date accessioned2017-05-08T21:58:52Z
date available2017-05-08T21:58:52Z
date copyrightNovember 2009
date issued2009
identifier other%28asce%29st%2E1943-541x%2E0000101.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/67947
description abstractThis paper presents results from an investigation of the behavior of unstiffened thin steel plate shear wall (SPSW) having a regular pattern of openings (a.k.a. perforated SPSW). Finite element monotonic pushover analyses were conducted, first on a series of individual perforated strips with variation in perforation diameter, to develop a fundamental understanding of the behavior of complete perforated SPSW, then on a corresponding series of complete perforated SPSW having various perforation diameters. Three different sets of wall boundary conditions are considered, namely: flexible beam laterally braced, rigid floor, and rigid beam. Though some differences between the SPSW panel strips and the individual strip results are observed at large monitored strain, at lower monitored strain however the two models are in a good agreement. Based on the analytical results design recommendations of these perforated SPSWs are presented. The shear strength of a SPSW infill plate having a pattern of multiple regularly spaced circular perforations can be calculated as a function of the shear strength of a solid panel, perforation diameter, and distance between perforations.
publisherAmerican Society of Civil Engineers
titleFinite-Element Investigation and Design Recommendations for Perforated Steel Plate Shear Walls
typeJournal Paper
journal volume135
journal issue11
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0000061
treeJournal of Structural Engineering:;2009:;Volume ( 135 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record