Show simple item record

contributor authorMelissa A.
contributor authorStewart
contributor authorJohn S.
contributor authorMcCartney
date accessioned2017-05-08T21:48:21Z
date available2017-05-08T21:48:21Z
date copyrightApril 2014
date issued2014
identifier other%28asce%29he%2E1943-5584%2E0000012.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62874
description abstractThis study presents a centrifuge modeling approach to characterize the transient thermomechanical response of energy foundations during heating-cooling cycles to provide data for calibration and validation of soil-structure interaction models. This study focuses on the response of a scale-model energy foundation installed in an unsaturated silt layer with end-bearing boundary conditions. The foundation response was assessed using embedded strain gauges and thermocouples. Other variables monitored include foundation head displacements, soil surface displacements, and changes in temperature and volumetric water content in the unsaturated silt at different depths and radial locations. Measurements during the initial heating process indicate that the thermal axial stress is greater near the toe of the foundation as a result of the restraint associated with mobilization of side shear resistance along the length of the foundation. The thermal axial strains were close to the free-expansion thermal strain near the soil surface and decreased with depth. The thermal axial displacements calculated by integrating the thermal axial strains correspond well with the independently measured head displacements. The mobilized side stresses calculated from the thermal axial stresses increased with height and were consistent with the shear strength of unsaturated silt. During successive heating-cooling cycles, slight decreases in upward thermal head displacement were observed because of changes in the stiffness of the unsaturated soil from thermally induced water flow away from the foundation and potential downdrag effects. However, little change in the thermal axial stress was observed during the heating-cooling cycles.
publisherAmerican Society of Civil Engineers
titleCentrifuge Modeling of Soil-Structure Interaction in Energy Foundations
typeJournal Paper
journal volume140
journal issue4
journal titleJournal of Geotechnical and Geoenvironmental Engineering
identifier doi10.1061/(ASCE)GT.1943-5606.0001061
treeJournal of Geotechnical and Geoenvironmental Engineering:;2014:;Volume ( 140 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record