Show simple item record

contributor authorBritta
contributor authorBienen
contributor authorMark Jason
contributor authorCassidy
date accessioned2017-05-08T21:48:07Z
date available2017-05-08T21:48:07Z
date copyrightDecember 2013
date issued2013
identifier other%28asce%29gt%2E1943-5606%2E0000960.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62765
description abstractThis paper addresses a three-dimensional consolidation problem through experimentation in a geotechnical centrifuge. During a discontinuous footing installation, which is typical for mobile offshore drilling rigs, periods of consolidation are encountered as part of the installation process. While this is acknowledged to expose the platforms to potentially severe consequences due to the risk of rapid uncontrolled leg penetration, to date no method has been established to predict this risk and thus enable its mitigation. The findings of this experimental study show that while the peak penetration resistance postconsolidation is mainly influenced by the duration of the consolidation period, as is expected, the load magnitude held during consolidation also significantly influences the severity of capacity reduction postpeak. The consolidation and postconsolidation behavior is discussed for various penetration depths relevant to typical jack-up installations in the field. The key findings of this study are summarized in nondimensional graphs to facilitate application in practice.
publisherAmerican Society of Civil Engineers
titleSet Up and Resulting Punch-Through Risk of Jack-Up Spudcans during Installation
typeJournal Paper
journal volume139
journal issue12
journal titleJournal of Geotechnical and Geoenvironmental Engineering
identifier doi10.1061/(ASCE)GT.1943-5606.0000943
treeJournal of Geotechnical and Geoenvironmental Engineering:;2013:;Volume ( 139 ):;issue: 012
contenttypeFulltext