contributor authorJohn H. O’Haver
contributor authorRobert Walk
contributor authorBoonyarach Kitiyanan
contributor authorJeffrey H. Harwell
contributor authorDavid A. Sabatini
date accessioned2017-05-08T21:41:42Z
date available2017-05-08T21:41:42Z
date copyrightJanuary 2004
date issued2004
identifier other%28asce%290733-9372%282004%29130%3A1%284%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/59653
description abstractLaboratory studies and model results were utilized to design packed tower and hollow fiber air stripping units which were field tested with a contaminant-laden surfactant stream. Field units were operated at a 1.9 liter/min liquid flow rate with air/liquid ratios ranging from 20 to 50 and system temperatures ranging from 10 to 37°C. Tri- and tetrachloroethylene were analyzed as the target components. When properly operated, the field units successfully met or exceeded the targeted 90% removal efficiency. As expected, high air to liquid flow rates and higher system temperatures achieved high removal efficiencies while solutions with high surfactant and contaminant concentrations were the most difficult to treat.
publisherAmerican Society of Civil Engineers
titlePacked Column and Hollow Fiber Air Stripping of a Contaminant-Surfactant Stream
typeJournal Paper
journal volume130
journal issue1
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)0733-9372(2004)130:1(4)
treeJournal of Environmental Engineering:;2004:;Volume ( 130 ):;issue: 001
contenttypeFulltext