description abstractFor a wastewater collection system, the maximum volume that can be attained with an inline storage pipe is shown to occur when the pipe diameter is chosen to be 2/3 of the thickness of soil profile available for burial of the storage pipe, irrespective of pipeline slope.
publisherAmerican Society of Civil Engineers
titleChoosing Pipe Diameter to Maximize Inline Storage Volume
typeJournal Paper
journal volume135
journal issue8
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)EE.1943-7870.0000030
treeJournal of Environmental Engineering:;2009:;Volume ( 135 ):;issue: 008