description abstractConstruction of buildings using a slab on grade and belled drilled piers to support column loads in central Mississippi has performed poorly. Similar buildings where the first floor was poured on 15.2 cm (6 in.) cardboard box forms have not fared much better. The first floor of this building was a slab on grade that was dowelled to a grid of grade beams. The grade beams were dowelled to drilled piers. The top of the expansive Yazoo clay varied from 1.8 to 3.66 m (5.9–12 ft) deep. High swell pressures developed under the slab and began to lift the building. A frame analysis showed that foundation movements were significantly changing the stresses of the structural steel frame. About half of the drilled piers of the building were found to be damaged near the connection with the grade beam. Two piers had separations of 10.2 and 8.9 cm (4 and 3.5 in.). During the foundation repair, the building frame was releveled and eight damaged piers were replaced. Recommendations to reduce the risk of this kind of damage were made.
publisherAmerican Society of Civil Engineers
titleInvestigation and Repair of a Four-Story Building Damaged by Yazoo Clay
typeJournal Paper
journal volume25
journal issue1
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0000075
treeJournal of Performance of Constructed Facilities:;2011:;Volume ( 025 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record