Show simple item record

contributor authorDillon S. Lunn
contributor authorSami H. Rizkalla
date accessioned2017-05-08T21:36:08Z
date available2017-05-08T21:36:08Z
date copyrightApril 2011
date issued2011
identifier other%28asce%29cc%2E1943-5614%2E0000091.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/57203
description abstractThis paper evaluates the effectiveness of different externally bonded glass fiber–reinforced polymer (GFRP) systems for increasing the out-of-plane resistance of infill masonry walls to loading. The research included a comprehensive experimental program comprising 14 full-scale specimens, including four unstrengthened (control) specimens and 10 strengthened specimens. To simulate the boundary conditions of infill walls, all specimens consisted of a reinforced concrete (RC) frame, simulating the supporting RC elements of a building superstructure, which was infilled with solid concrete brick masonry. The specimens were loaded out-of-plane using uniformly distributed pressure to simulate the differential (suction) pressure induced by a tornado. Parameters investigated in the experimental program included aspect ratio, FRP coverage ratio, number of masonry wythes, and type of FRP anchorage. Test results indicated that the type of FRP anchorage had a significant effect on the failure mode. Research findings concluded that GFRP strengthening of infill masonry walls is effective in increasing the out-of-plane load-carrying capacity when proper anchorage of the FRP laminate is provided.
publisherAmerican Society of Civil Engineers
titleStrengthening of Infill Masonry Walls with FRP Materials
typeJournal Paper
journal volume15
journal issue2
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000088
treeJournal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record