Show simple item record

contributor authorJohn Leander
contributor authorRaid Karoumi
date accessioned2017-05-08T21:35:16Z
date available2017-05-08T21:35:16Z
date copyrightJuly 2012
date issued2012
identifier other%28asce%29be%2E1943-5592%2E0000293.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/56835
description abstractBy in situ measurements, the real distribution of stress ranges caused by service loads can be recorded. Inherent effects in the measured response as disturbance can, however, create puzzles in the interpretation of the result. In large monitoring campaigns, it is not possible to examine the result from every gauge over the whole measured period by visual control. An approach for a quality assurance of the measured response is presented here based on established statistical methods. The stress range spectra, the product of the monitoring program intended for fatigue assessment, are analyzed. The aim is to find deviant spectra and identify corrupt gauges. An additional aspect is the length of the monitoring period, which is the required duration for obtaining a stable result. A case study of a monitored Swedish steel railway bridge is incorporated to exemplify the approaches. Some statistical distributions for the monitored stress ranges are also presented and incorporated in a fatigue assessment.
publisherAmerican Society of Civil Engineers
titleQuality Assurance of Measured Response Intended for Fatigue Life Prediction
typeJournal Paper
journal volume17
journal issue4
journal titleJournal of Bridge Engineering
identifier doi10.1061/(ASCE)BE.1943-5592.0000291
treeJournal of Bridge Engineering:;2012:;Volume ( 017 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)