description abstractThis study examines how design features, such as building envelope openings and compartmentalization, affect the wind pressure in typical low-rise buildings with gable and hip roofs. Wind-induced internal and external pressures were investigated by using a full-scale wind testing facility generically known as Wall of Wind (WOW). The test-building model was built with an optimal size of 2.74 m (9 ft) long, 2.13 m (7 ft) wide, and 2.13 m (7 ft) high. The model consisted of multiple dominant openings (doors with secondary openings and windows), roof ventilation devices (soffit vents, gooseneck roof vent, and roof turbine ventilators), and horizontal and vertical (ceiling and wall) internal assembly compartments. These features, together with a high Reynolds number (
publisherAmerican Society of Civil Engineers
titleOpening and Compartmentalization Effects of Internal Pressure in Low-Rise Buildings with Gable and Hip Roofs
typeJournal Paper
journal volume21
journal issue1
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)AE.1943-5568.0000101
treeJournal of Architectural Engineering:;2015:;Volume ( 021 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record