description abstractFiber-reinforced polymer (FRP) hollow tubes are used in structural applications, such as utility poles and pipelines. Concrete-filled FRP tubes (CFFTs) are also used as piles and bridge piers. Applications such as poles and marine piles are typically governed by cyclic bending. In this paper, the fatigue behavior of glass-FRP filament-wound tubes is studied using coupons cut from the tubes. Several coupon configurations were first examined in 24 tension and five compression monotonic loading tests. Fatigue tests were then conducted on 81 coupons to examine several parameters; namely, loading frequency as well as maximum-to-ultimate
publisherAmerican Society of Civil Engineers
titleFatigue Life Assessment and Static Testing of Structural GFRP Tubes Based on Coupon Tests
typeJournal Paper
journal volume12
journal issue2
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)1090-0268(2008)12:2(212)
treeJournal of Composites for Construction:;2008:;Volume ( 012 ):;issue: 002