Show simple item record

contributor authorAkhrawat Lenwari
contributor authorThaksin Thepchatri
contributor authorPedro Albrecht
date accessioned2017-05-08T21:30:51Z
date available2017-05-08T21:30:51Z
date copyrightFebruary 2006
date issued2006
identifier other%28asce%291090-0268%282006%2910%3A1%2869%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54354
description abstractThis paper addresses the debonding strength of partial-length, adhesively bonded carbon fiber-reinforced polymer (CFRP) plates that are used to strengthen steel beams. Bonded CFRP plates tend to debond under static and fatigue loadings because of the very high stress field at the plate end. Such failures limit the application of CFRP plates. Static and fatigue tests show that the stress intensity factor governs the debonding strength. The steel/adhesive corner was the locus of debond initiation. The effects of the following parameters on stress intensity factors are discussed: plate thickness, plate modulus, bondline thickness, adhesive modulus, and adhesive spew-fillet angle. The stress intensity factors are calculated using the Betti’s law-based reciprocal work contour integral method (RWCIM). The parametric study results indicate that the stress intensity factors cannot be used to represent the severity of the corner as the adhesive spew-fillet angle (and singularity) changes. Therefore, the use of stress intensity factors as a failure criterion for the purpose of predicting debonding strength is limited to the same spew-fillet angle.
publisherAmerican Society of Civil Engineers
titleDebonding Strength of Steel Beams Strengthened with CFRP Plates
typeJournal Paper
journal volume10
journal issue1
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)1090-0268(2006)10:1(69)
treeJournal of Composites for Construction:;2006:;Volume ( 010 ):;issue: 001