Show simple item record

contributor authorD. C. Keelor
contributor authorY. Luo
contributor authorC. J. Earls
contributor authorW. Yulismana
date accessioned2017-05-08T21:30:39Z
date available2017-05-08T21:30:39Z
date copyrightAugust 2004
date issued2004
identifier other%28asce%291090-0268%282004%298%3A4%28289%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54243
description abstractThis paper reports on the field study of a steel stringer-fiber reinforced polymer (FRP) deck composite bridge in Pennsylvania. The objective of the study is to assess the effective compression flange width in the FRP deck and floor systems when they act compositely with underlying steel girders at service conditions. The research results reported herein support the notion of employing a design approach, for both interior and exterior girders of a composite floor system, that is philosophically consistent with current practice related to steel girders acting compositely with concrete decking. It appears from the results presented herein that FRP decks and floors acting compositely with underlying steel girders exhibit an effective width that is close to the actual girder spacing for interior beams, and approximately one-half this value for exterior beams.
publisherAmerican Society of Civil Engineers
titleService Load Effective Compression Flange Width in Fiber Reinforced Polymer Deck Systems Acting Compositely with Steel Stringers
typeJournal Paper
journal volume8
journal issue4
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)1090-0268(2004)8:4(289)
treeJournal of Composites for Construction:;2004:;Volume ( 008 ):;issue: 004
contenttypeFulltext