Show simple item record

contributor authorLarry C. Muszynski
contributor authorMichael R. Purcell
date accessioned2017-05-08T21:30:33Z
date available2017-05-08T21:30:33Z
date copyrightMay 2003
date issued2003
identifier other%28asce%291090-0268%282003%297%3A2%2898%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/54182
description abstractTwo concrete structures and three air-entrained concrete (AEC) masonry walls were subjected to two, high explosive detonations. The concrete structures were placed at a stand-off distance such that medium damage was expected. The stand-off distance of the AEC-masonry walls was reduced on each successive detonation until breaching occurred. The two concrete structures retrofitted with composite materials were subjected to air-blast loading at a stand-off distance of approximately 14.6 m. The structures were constructed such that each long side of the structure contained a wall retrofitted with a composite material and a wall left bare as a control. Both concrete structures exhibited less residual displacement on the walls strengthened with composite materials than the bare control walls.
publisherAmerican Society of Civil Engineers
titleUse of Composite Reinforcement to Strengthen Concrete and Air-Entrained Concrete Masonry Walls against Air Blast
typeJournal Paper
journal volume7
journal issue2
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)1090-0268(2003)7:2(98)
treeJournal of Composites for Construction:;2003:;Volume ( 007 ):;issue: 002