Show simple item record

contributor authorS. J. Jillson
contributor authorM. F. Dahab
contributor authorW. E. Woldt
contributor authorR. Y. Surampalli
date accessioned2017-05-08T21:29:44Z
date available2017-05-08T21:29:44Z
date copyrightJuly 2001
date issued2001
identifier other%28asce%291090-025x%282001%295%3A3%28153%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53660
description abstractThis paper reports the performance of two horizontal subsurface flow constructed wetland systems in the removal of pathogen and pathogen indicators under variable loading and operating conditions. The two constructed wetland systems evaluated under this project are located near Lincoln, Nebr. Firethorn is located in a small housing community and Rogers Farm at a rural single-family dwelling. Samples at Firethorn were collected at the wetland cell influent, effluent, and sand filter effluent (system effluent) from June 1996 through April 2000 and at the influent and effluent points from Rogers Farm from June 1999 through April 2000. The main monitoring parameters were fecal coliform at both sites and
publisherAmerican Society of Civil Engineers
titlePathogen and Pathogen Indicator Removal Characteristics in Treatment Wetlands Systems
typeJournal Paper
journal volume5
journal issue3
journal titlePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management
identifier doi10.1061/(ASCE)1090-025X(2001)5:3(153)
treePractice Periodical of Hazardous, Toxic, and Radioactive Waste Management:;2001:;Volume ( 005 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record