Show simple item record

contributor authorJean-Louis Briaud
contributor authorMarc Ballouz
contributor authorGeorge Nasr
date accessioned2017-05-08T21:27:01Z
date available2017-05-08T21:27:01Z
date copyrightJuly 2000
date issued2000
identifier other%28asce%291090-0241%282000%29126%3A7%28640%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/51917
description abstractThree bored piles were built and tested at the National Geotechnical Experimentation Sites, at Texas A&M University, to gather data on the reliability of large-strain dynamic methods to predict the static capacity of bored piles. The three piles had a nominal diameter of 0.915 m, a nominal length of 10 m, and some planned and unplanned defects. The piles were first subjected to a static load test and then four companies were asked to perform dynamic tests—namely, Statnamic and drop weight tests—and predict the static load test results. The paper shows the comparison between predicted and measured results.
publisherAmerican Society of Civil Engineers
titleStatic Capacity Prediction by Dynamic Methods for Three Bored Piles
typeJournal Paper
journal volume126
journal issue7
journal titleJournal of Geotechnical and Geoenvironmental Engineering
identifier doi10.1061/(ASCE)1090-0241(2000)126:7(640)
treeJournal of Geotechnical and Geoenvironmental Engineering:;2000:;Volume ( 126 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record