contributor authorC. L. Hanson
contributor authorM. D. Burgess
date accessioned2017-05-08T21:23:05Z
date available2017-05-08T21:23:05Z
date copyrightJanuary 1997
date issued1997
identifier other%28asce%291084-0699%281997%292%3A1%2837%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/49363
description abstractRecently developed integrated circuit technology and new reliable pressure transducers have made it possible to develop a battery-operated system to automatically fill class A evaporation pans from stored water. The system records and stores the average of 12 pan level records during a 1 min time period at the end of each 15 min period for later transmission to a central data storage facility. The measurement sensitivity of the system is 0.02 cm of evaporation over a range of 3.5 cm. A field calibration of the system showed that there was a very good (
publisherAmerican Society of Civil Engineers
titleTime‐ and Level‐Controlled Filling System for Class A Evaporation Pans
typeJournal Paper
journal volume2
journal issue1
journal titleJournal of Hydrologic Engineering
identifier doi10.1061/(ASCE)1084-0699(1997)2:1(37)
treeJournal of Hydrologic Engineering:;1997:;Volume ( 002 ):;issue: 001
contenttypeFulltext