Show simple item record

contributor authorMehran Keshavarzian
contributor authorCharles H. Priebe
date accessioned2017-05-08T21:22:41Z
date available2017-05-08T21:22:41Z
date copyrightNovember 2002
date issued2002
identifier other%28asce%291084-0680%282002%297%3A4%28141%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/49059
description abstractMost utility engineers in the United States use the National Electrical Safety Code (NESC) to determine minimum structural loading requirements for the design of transmission and distribution pole structures. The NESC specifies two weather loadings—combined ice and wind loading (rule 250B) and extreme wind loading (rule 250C). However, the current NESC excludes poles with heights above ground of 60 ft or less from the extreme wind loading (rule 250C) design requirement. ASCE 7-98 prescribes extreme wind load requirements for the design of buildings and other structures and contains no extreme wind load exclusion provision for short structures. This paper reviews the adequacy of the current NESC 60 ft exclusion provision for the design of poles located in the 90–140 mph 3 s gust wind speed based on ASCE 7-98.
publisherAmerican Society of Civil Engineers
titleWind Performance of Short Utility Pole Structures
typeJournal Paper
journal volume7
journal issue4
journal titlePractice Periodical on Structural Design and Construction
identifier doi10.1061/(ASCE)1084-0680(2002)7:4(141)
treePractice Periodical on Structural Design and Construction:;2002:;Volume ( 007 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)