Show simple item record

contributor authorHerbert L. Bill Jr.
date accessioned2017-05-08T21:21:55Z
date available2017-05-08T21:21:55Z
date copyrightMarch 2000
date issued2000
identifier other%28asce%291076-0431%282000%296%3A1%2835%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48593
description abstractAISC has proposed an alternative to the use of joist girders. That proposal is based on a system that was originally developed for bridge structures. The concept was first applied to architectural structures many years ago, but was abandoned for several reasons. One principle reason for this was the system's dependence on artificial loads to balance the presence of real loads. Because of this, the system may be very susceptible to overload. The use of the Gerber System will produce a structure that is nearly half the depth of a Joist Girder System. That should be the primary reason for choosing to use the Gerber System. This paper proposes a design approach that allows this system to be used with confidence and safety. The proposed approach is based on a stiffness analysis instead of a strength analysis. The purpose of this paper is to encourage the safe use of the Gerber Framing System.
publisherAmerican Society of Civil Engineers
titleCantilever and Suspended Span Roof Framing System
typeJournal Paper
journal volume6
journal issue1
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)1076-0431(2000)6:1(35)
treeJournal of Architectural Engineering:;2000:;Volume ( 006 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record