Show simple item record

contributor authorStephen N. Flanders
contributor authorNorbert E. Yankielun
date accessioned2017-05-08T21:21:52Z
date available2017-05-08T21:21:52Z
date copyrightDecember 1998
date issued1998
identifier other%28asce%291076-0431%281998%294%3A4%28135%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48554
description abstractThe writers have devised a prototype cable-based roof moisture detection and location system (U.S. Patent 5,648,724) that was tested in simulated conditions. The detection system can use a variety of principles to monitor roofing for the presence of moisture. The location system uses a metallic time-domain reflectometer (MTDR) to locate a suspected wet area by sending an electromagnetic pulse or step signal down the sensor cable and looking for reflections caused by a change in the dielectric constant surrounding the cable due to the presence of a wet area. Tests revealed the MTDR technique to be sensitive and able to locate the position of less than 1 L (0.22 gal.) of water within 0.3 m (1 ft) over 30.5 m (100 ft) of cable. Where multiple regions of wetting were present along the length of the cable, it was possible to locate each boundary between wet and dry.
publisherAmerican Society of Civil Engineers
titleLaboratory Tests of Cable-Based Roof Moisture Detection System
typeJournal Paper
journal volume4
journal issue4
journal titleJournal of Architectural Engineering
identifier doi10.1061/(ASCE)1076-0431(1998)4:4(135)
treeJournal of Architectural Engineering:;1998:;Volume ( 004 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record