Show simple item record

contributor authorLaurie S. McNeill
contributor authorMarc Edwards
date accessioned2017-05-08T21:21:18Z
date available2017-05-08T21:21:18Z
date copyrightDecember 2003
date issued2003
identifier other%28asce%291076-0342%282003%299%3A4%28145%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/48189
description abstractThe new Enhanced Coagulation Rule requires that drinking water utilities improve the removal of natural organic matter from their water. One common method of doing so is to “enhance” the performance of existing coagulation processes by increasing the coagulant dose, changing the coagulant type, or lowering the coagulation pH. There is growing concern that these treatment changes might cause degradation of cement and metallic components of drinking water treatment plant infrastructure. In a survey of enhanced coagulation impacts at 275 water utilities, 24% have reportedly already seen at least some infrastructure degradation. A comprehensive literature review highlights the potential causes for the degradation observed by utilities, and recommendations are provided to guide utilities seeking to minimize degradation and repair existing damage.
publisherAmerican Society of Civil Engineers
titleDegradation of Drinking Water Treatment Plant Infrastructure from Enhanced Coagulation
typeJournal Paper
journal volume9
journal issue4
journal titleJournal of Infrastructure Systems
identifier doi10.1061/(ASCE)1076-0342(2003)9:4(145)
treeJournal of Infrastructure Systems:;2003:;Volume ( 009 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record