Show simple item record

contributor authorKeita Suzumura
contributor authorShun-ichi Nakamura
date accessioned2017-05-08T21:17:36Z
date available2017-05-08T21:17:36Z
date copyrightFebruary 2004
date issued2004
identifier other%28asce%290899-1561%282004%2916%3A1%281%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/45904
description abstractIt was found from field surveys that suspension bridge cables were under severe corrosion environments due to the water and high temperature inside the cable. Corrosion environments depended on the wire positions inside the cables. Wires were found to be continuously wet at the side, wet at night and dry during the day on the top, highly humid at the center, and soaked in the water at the bottom. Accelerated corrosion tests using galvanized steel wires showed that the side wires were most severely corroded, the bottom wires were also significantly corroded, but the upper and the center wires were rarely corroded. These phenomena agreed with the actual cable corrosion. The tests also showed that galvanized steel wires did not corrode when they were kept with a relative humidity below 60%, but became corrosive with the higher relative humidity. Larger amounts of sodium chloride increased corrosion considerably. The corrosion rate also exponentially increased with temperature. It was predicted that the zinc layer would be consumed within 10 years when wires were kept in the wet or soaked environments, 34 years with a relative humidity of 100%, and 211 years with a relative humidity below 60%.
publisherAmerican Society of Civil Engineers
titleEnvironmental Factors Affecting Corrosion of Galvanized Steel Wires
typeJournal Paper
journal volume16
journal issue1
journal titleJournal of Materials in Civil Engineering
identifier doi10.1061/(ASCE)0899-1561(2004)16:1(1)
treeJournal of Materials in Civil Engineering:;2004:;Volume ( 016 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record