Show simple item record

contributor authorS. D. Dimitrakis
contributor authorF. V. Lawrence
date accessioned2017-05-08T21:17:22Z
date available2017-05-08T21:17:22Z
date copyrightFebruary 2002
date issued2002
identifier other%28asce%290899-1561%282002%2914%3A1%2884%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/45750
description abstractA high degree of local bending was observed in the beam flange of a beam-to-column connection modeled with 3D finite-element analyses. The regions of high stress concentration were shown to occur at the weld access hole and the intersection of the bottom beam flange and column flange. The use of a specially designed part termed a “stress diffuser” with a beam-to-column connection, in which the beam web and bottom beam flange are separated near the weld access hole, was found to eliminate the high stress concentration at the weld access hole and reduce the high degree of local bending in the beam flange by 49%. The maximum principal stress at 2.54 mm from the column face was reduced by 31%.
publisherAmerican Society of Civil Engineers
titleApplication of Stress Diffusers to Beam-to-Column Connection
typeJournal Paper
journal volume14
journal issue1
journal titleJournal of Materials in Civil Engineering
identifier doi10.1061/(ASCE)0899-1561(2002)14:1(84)
treeJournal of Materials in Civil Engineering:;2002:;Volume ( 014 ):;issue: 001
contenttypeFulltext