contributor authorDimos Polyzois
contributor authorWalter J. Muzyczka
date accessioned2017-05-08T21:16:48Z
date available2017-05-08T21:16:48Z
date copyrightNovember 1994
date issued1994
identifier other%28asce%290899-1561%281994%296%3A4%28495%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/45385
description abstractThe vertical lift fixed‐wheel gate is a common type of control gate found at hydroelectric generating stations. The material used for the wheels of such gates ranges from cast iron for the older vintage stations to alloy and low‐carbon steels in more modern stations. In recent years, several cast‐iron wheels on such gates have failed in service. An experimental program, sponsored by Manitoba Hydro, was undertaken at the University of Manitoba to study the performance characteristics of cast‐iron wheels and to determine their failure capacity under static loading conditions. Eleven 685‐mm‐diameter cast‐iron wheels obtained from a spillway gate at the McArthur Falls Generating Station in Manitoba were tested to failure under radial and a combination of radial and lateral loads. The material properties were obtained from standard coupon testing. In addition to the experimental work, the elastic behavior of cast‐iron gate wheels was investigated using the ANSYS finite‐element (FE) program. The results from the experimental program and the finite‐element analysis were compared to the results predicted by current design criteria and a number of recommendations for improving these criteria were made.
publisherAmerican Society of Civil Engineers
titleBehavior of Cast‐Iron Spillway Gate Wheels
typeJournal Paper
journal volume6
journal issue4
journal titleJournal of Materials in Civil Engineering
identifier doi10.1061/(ASCE)0899-1561(1994)6:4(495)
treeJournal of Materials in Civil Engineering:;1994:;Volume ( 006 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record