Show simple item record

contributor authorMohammed A. Amjad
date accessioned2017-05-08T21:14:43Z
date available2017-05-08T21:14:43Z
date copyrightMay 1997
date issued1997
identifier other%28asce%290887-3828%281997%2911%3A2%2876%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/44118
description abstractFifty-four existing buildings (five to eight years old) and 54 construction sites were surveyed in Riyadh, Saudi Arabia. Different types of masonry walls were used, mainly as non–load-bearing reinforced or unreinforced and cavity walls. It was found that the causes of cracks and failures were attributed to structural changes, temperature changes, and foundation settlement deficiencies. It was also found that these failures and cracks can be minimized by adopting proper masonry design and construction. This can be accomplished by introducing movement joints, bed-joint reinforcement, adequate support and anchoring, and good artisanship and supervision.
publisherAmerican Society of Civil Engineers
titleDeficiencies and Failures of Non–Load-Bearing Masonry Walls in Riyadh
typeJournal Paper
journal volume11
journal issue2
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)0887-3828(1997)11:2(76)
treeJournal of Performance of Constructed Facilities:;1997:;Volume ( 011 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record