Show simple item record

contributor authorLu, Yuan-Chiao
contributor authorMojumder, Joy
contributor authorAlshareef, Ahmed
contributor authorWang, Wen-Tung
contributor authorPrince, Jerry L.
contributor authorBayly, Philip
contributor authorButman, John A.
contributor authorPham, Dzung L.
date accessioned2026-08-23T08:36:20Z
date available2026-08-23T08:36:20Z
date copyright2026/05/01
date issued2026
identifier issn0148-0731
identifier otherbio-25-1354.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316797
description abstractAbstract. Tagged magnetic resonance imaging (MRI) has been successfully applied for noninvasive quantification of in vivo brain deformation, enabling characterization of strain distributions under mild, noninjurious loading conditions. Previously, the double trigger (DT) method was proposed to improve temporal consistency, where an initial trigger initiates the MRI tagging pulse and a second trigger initiates image acquisition. However, this approach has two disadvantages: (1) the initial trigger was mechanical and susceptible to misalignment during connection to a fiber optic cable; (2) the time history of the tagged MRI acquisition was constrained to the interval between the initial and second triggers, thereby limiting the overall acquisition duration. In this work, a late trigger (LT) approach is proposed to eliminate mechanical triggering and the use of a fiber optic cable, reduce tag fading, and enable a longer duration time history. Gel phantom experiments demonstrate that both DT and LT approaches yield consistent strain patterns and angular kinematics. Similarly, angular motion and in-plane strain measured using in vivo two-dimensional (2D) tagged MRI show strong agreement between the DT and LT approaches; nonetheless, LT consistently provides improved tag contrast, signal-to-noise ratio (SNR), and anatomical delineation. In in vivo three-dimensional (3D) testing, LT method produces 95th percentile maximum principal strain (MPS95) strain values that closely align with those of the DT method across multiple brain regions. Collectively, the LT method demonstrates performance comparable to DT in both phantom and in vivo experiments, highlighting its potential as a physiologically robust and technically advantageous strategy for measuring brain deformation.
publisherThe American Society of Mechanical Engineers (ASME)
titleLate Triggering in Tagged Magnetic Resonance Imaging for in vivo Characterization of Brain Biomechanics During Head Rotation
typeJournal Paper
journal volume148
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4071580
journal fristpage3475
journal lastpage3481
page7
treeJournal of Biomechanical Engineering:;2026:;volume( 148 ):;issue:005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record