Show simple item record

contributor authorVervenne, Thibault
contributor authorVermeeren, Nic
contributor authorDemeersseman, Nele
contributor authorFehervary, Heleen
contributor authorPeirlinck, Mathias
contributor authorKuhl, Ellen
contributor authorFamaey, Nele
date accessioned2026-08-23T08:34:14Z
date available2026-08-23T08:34:14Z
date copyright2026/05/01
date issued2026
identifier issn0148-0731
identifier otherbio-25-1197.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316744
description abstractAbstract. Understanding the physiological condition of the vascular system is critical to explain, treat, and manage vascular disease. Numerous experimental and computational studies characterize the mechanical behavior of arterial tissue under controlled laboratory conditions. However, translating this knowledge into physiologically realistic conditions remains challenging. Key difficulties include selecting suitable and relevant test methods, minimizing uncertainty, and ensuring robust model validation. Here, we present a novel integrative approach to translate laboratory experiments on arterial samples into clinically relevant pressure–diameter behavior. We perform controlled planar-biaxial tests on carotid arteries under three stretch ratios and generate axial and circumferential stress–stretch data to calibrate a fiber-reinforced soft tissue model. Using an analytical thick-walled cylindrical model, we predict subject-specific pressure–diameter behavior, informed by arterial prestretches from ring opening experiments. We systematically compare predictions against extension-inflation experiments on tubes from the same artery by applying controlled pairs of axial stretch and inner pressure, while recording outer diameter. We quantify prediction error in absolute and relative stretch regimes and evaluate the importance of the load-free reference dimensions. Results show how planar-biaxial tests probe different stretch regimes compared to extension-inflation deformations, leading to extrapolation of model predictions. We demonstrate how the constitutive material parameters can be fitted to different biomechanical loading conditions, and we assess the sensitivity of the simulations to axial stretch and circumferential prestretch. Only when those key model parameters are accurately captured and their uncertainty propagated, planar-biaxial stress–stretch data can reliably predict arterial pressure–diameter behavior.
publisherThe American Society of Mechanical Engineers (ASME)
titleStretching the Limits: From Planar-Biaxial Stress–Stretch to Arterial Pressure–Diameter
typeJournal Paper
journal volume148
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4070124
journal fristpage18
journal lastpage26
page9
treeJournal of Biomechanical Engineering:;2026:;volume( 148 ):;issue:005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record