Show simple item record

contributor authorGeorge, Subin P.
contributor authorVenkatesh, Krishnan
contributor authorKumar, Gurunathan Saravana
date accessioned2026-08-23T08:18:51Z
date available2026-08-23T08:18:51Z
date copyright2026/03/01
date issued2026
identifier issn0148-0731
identifier otherbio-25-1259.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316372
description abstractAbstract. Morphological models offer significant improvements over static vertebral models by providing predictive capabilities for personalized medicine and injury prevention. These models are invaluable for evaluating biomechanical implications of surgical outcomes and designing personalized rehabilitation plans. Traditional in vitro experiments are limited by the minimal shape variation in available populations. This study aims to assess the sensitivity of anthropometric features on the biomechanical responses of the L4–L5 lumbar functional spine unit (FSU) under moment loading conditions. A population of L4–L5 FSUs was generated using a Design of Experiment (DoE) framework. One Factor at a Time (OFAT) analysis at five levels and Constrained Lattice Hyper Cube Sampling (CLHS) with 200 samples were employed. Anthropometric variations in disc wedging angle, anteroposterior diameter, transverse diameter (TD), vertebral height, and facet sagittal angle were applied using ANSA BETA CAETM. Morphing operations ensured anatomical adaptability without compromising mesh quality. Sensitivity analysis was performed using Pearson's Correlation Coefficient to evaluate the relationship between anthropometric parameters and biomechanical responses, including range of motion, disc pressures, and facet contact forces (CF). Model responses were validated against in vitro experimental data to confirm biomechanical fidelity. Sensitivity analysis using linear regression coefficients identified transverse diameter (−0.99 against range of motion (ROM)), anteroposterior diameter (−0.97 against ROM), and disc wedging angle (0.90 against facet contact force) as the most influential input parameters across different loading scenarios. The Pearson correlation analysis further substantiated these findings, revealing strong linear associations between morphological variations and biomechanical responses. These trends exhibited good agreement with existing in vitro experimental data. This study highlights the importance of geometric variations in determining biomechanical responses of the L4–L5 FSU. The findings provide a framework for treatment planning, critical response prediction, and patient-specific surgical outcome evaluation, paving the way for advancements in personalized medicine and rehabilitation.
publisherThe American Society of Mechanical Engineers (ASME)
titleSensitivity Analysis of a Morphological Finite Element L4–L5 Functional Spine Unit for Biomechanical Responses
typeJournal Paper
journal volume148
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4070766
journal fristpage1757
journal lastpage1766
page10
treeJournal of Biomechanical Engineering:;2026:;volume( 148 ):;issue:003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record