Show simple item record

contributor authorYang, Xuesen
contributor authorZhao, Wei
contributor authorZhao, Qingjun
contributor authorMa, Yingqun
contributor authorRen, Sanqun
contributor authorLiu, Binbin
date accessioned2026-08-23T07:44:06Z
date available2026-08-23T07:44:06Z
date copyright2026/01/01
date issued2026
identifier issn2832-8450
identifier otherht-25-1114.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315521
description abstractAbstract. This study combines numerical simulations and experimental investigations to analyze the heat transfer characteristics of a liquid nitrogen (LN2) spray cooling system. The factors affecting system performance, including nozzle outlet diameter, spray cone angle, and spray height, were analyzed in relation to surface temperature distributions. The simulated results closely align with experimental data, showing a maximum deviation of 2.7%, which validates the numerical reliability of the two-phase flow model based on the Euler–Lagrange method. Experimental findings indicate that the spray cone angle of subcooled LN2 closely resembles that of kerosene under identical operating conditions. Our previous study found that a larger spray cone angle reduces temperature nonuniformity. Consequently, a wide-angle nozzle was designed to achieve a maximum spray cone angle of 128 deg at 5 MPa pressure by converting axial momentum into tangential momentum via the use of three tangential holes. As a result, the surface temperature nonuniformity (STNU) decreased by approximately 50 °C when the spray cone angle increased from 20 deg to 120 deg for a nozzle with a 4 mm outlet diameter. The study also demonstrates that heat transfer performance worsens as spray height increases, but STNU improves, indicating that heat transfer enhancement and STNU improvement cannot be achieved simultaneously. Increasing the spray height from 93 mm to 186 mm reduced heat transfer intensity, while the decrease in STNU enabled the identification of optimal spray heights that minimized STNU by over 16.8% and enhanced thermal uniformity.
publisherThe American Society of Mechanical Engineers (ASME)
titleNumerical and Experimental Study on Heat Transfer Performance and Surface Temperature Nonuniformity Improvement in Liquid Nitrogen Spray Cooling
typeJournal Paper
journal volume148
journal issue1
journal titleASME Journal of Heat and Mass Transfer
identifier doi10.1115/1.4069331
treeASME Journal of Heat and Mass Transfer:;2026:;volume( 148 ):;issue:001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record