Show simple item record

contributor authorMao, Wenli
contributor authorLi, Rui
contributor authorJiang, Xiaofeng
contributor authorSun, Shizhong
contributor authorJin, Baosheng
contributor authorWang, Xiaojia
date accessioned2026-08-23T07:38:00Z
date available2026-08-23T07:38:00Z
date copyright2026/08/01
date issued2026
identifier issn1948-5085
identifier othertsea-25-1516.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315379
description abstractAbstract. To address the challenge of frequent pressure fluctuations in insulated compressed air thermal storage systems, this study develops a pressurized water thermal storage double-sphere tank solution with nitrogen pressure control as the key technology. By computational fluid dynamics modeling and process simulation, the flow process and energy conversion between pressurized water and nitrogen during the operational cycle were thoroughly investigated. Additionally, long-term dynamic simulations were conducted to extensively explore the dynamic response characteristics of the temperature and pressure field in tanks under different thermal storage temperatures, flowrates, and cycle numbers. The research results are as follows: first, the pressure changes of the system follow a trend of first decreasing, then remaining constant, then increasing, and finally decreasing during a cycle. No evaporation occurs because the minimum pressure remains above the saturation. The obvious temperature decrease is observed at the second static stage, while the cold tank temperature remains constant. Second, the differences in the resistance coefficient result in the nonlinear relationship between heat storage flowrate and gas pressure. At a high flowrate of 105.79 kg/s, the pressure reduction remains moderate. Finally, both the gas temperature and pressure field have reached equilibrium after three cycles, with the maximum pressure (1.42 MPa) occurring at the end of the heat release stage. The initial temperature and pressure of the next cycles rapidly increase because of heating, which is the main difference between them. In summary, the stable operating temperature for the pressurized water thermal storage system under this model should be less than 458 K, and the design pressure should be 1.6 MPa.
publisherThe American Society of Mechanical Engineers (ASME)
titleStable Operation Characteristics of the Pressurized Water Thermal Storage Tank System Based on Nitrogen Pressure Control
typeJournal Paper
journal volume18
journal issue8
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4070678
journal fristpage140
journal lastpage149
page10
treeJournal of Thermal Science and Engineering Applications:;2026:;volume( 018 ):;issue:008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record