Show simple item record

contributor authorJia, Wenbo
contributor authorWang, Teng
contributor authorZhao, Baohua
contributor authorHuang, Wenzhuo
contributor authorDuan, Yuzhou
contributor authorYu, Zuoqing
contributor authorLing, Jie
date accessioned2026-08-23T07:31:48Z
date available2026-08-23T07:31:48Z
date copyright2025/12/01
date issued2025
identifier issn1942-4302
identifier otherjmr-25-1228.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4315227
description abstractAbstract. Robotic-assisted lumbar puncture (LP) has demonstrated significant advantages over manual procedures in terms of accuracy and repeatability, with robotic-assisted needle insertion devices (RNIDs) serving as the core component for accurate needle placement. However, current RNIDs still encounter critical limitations in needle tip deflection and complex construction. The patient-specific design, based on preoperative imaging and tissue mechanical properties, may potentially improve the aforementioned issues. This article proposes a one-degree-of-freedom (1-DOF) patient-specific RNID to enhance the insertion accuracy. The 1-DOF motion coupling both insertion and rotation is achieved through a replaceable helical-type inner liner bush (RHILB), which functions as the RNID’s core transmission component. The RHILB features a patient-specific insertion-rotation ratio (IRR) determined from preoperative X-ray imaging. Utilizing three-dimensional (3D) printing technology, these customized RHILBs can be rapidly manufactured and seamlessly integrated into the RNID via a plug-and-play interface, enabling quick replacement for different patients. The preliminary experiments are conducted first to demonstrate the optimal IRRs for different materials. The kinematic model of the core component, i.e., the RHILB, is established. A fifth-order transition curve equation is formulated to eliminate impacts on velocity and acceleration during insertion. Prototype experiments are conducted to evaluate the insertion accuracy and patient-specific issues. Comparative results show that the variable-IRR design reduces mean needle tip deflection by 27.73% (p<0.05) and 62.40% (p<0.001) than the constant IRR design.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign of a Patient-Specific Needle Insertion Device for Accurate and Safe Lumbar Puncture
typeJournal Paper
journal volume17
journal issue12
journal titleJournal of Mechanisms and Robotics
identifier doi10.1115/1.4069673
journal fristpage228
journal lastpage231
page4
treeJournal of Mechanisms and Robotics:;2025:;volume( 017 ):;issue:012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record