description abstractAbstract. While fascicular elastic fibers have been shown to significantly affect mechanical properties of tendon in stress relaxation and ramp to failure testing, the contribution of elastin to fatigue properties has only recently been investigated. This study expanded upon recent fatigue-to-failure data in wild-type and limb-specific elastin knockdown mice (Prx1Cre+;Elnfl/fl) by halting tests at 50% of cyclic fatigue (based on normalized strain) instead of completing tests to full tissue failure. Following 50% fatigue loading, Achilles (AT) and tibialis anterior (TB) tendons were subjected to subsequent stress relaxation and ramp to failure testing, enabling comparison to prior properties of nondamaged tendons to determine the effects of subfailure fatigue. Indeed, multiple properties (e.g., ultimate stress and linear modulus) were decreased following fatigue loading, especially in elastin-deficient tendons, and genotype-dependent differences in stress relaxation properties were observed. Quantitative metrics of damage (i.e., collagen denaturation and fiber kinking) were not different between wild-type and elastin knockdown tendons as observed previously following fatigue-induced failure, suggesting that tendon damage develops later in the fatigue lifecycle. In addition, results suggest that elastin mediates collagen fiber alignment more in ATs than TBs, providing evidence that the different effects of elastin on tendon mechanics rely on microstructural mechanisms that vary by tendon type. Clinically, results of this study suggest that individuals with deficient or depleted elastin may experience impaired recovery following repetitive tendon loading, which could have downstream effects on subsequent damage accumulation and tissue remodeling that should be investigated further in future studies.
publisherThe American Society of Mechanical Engineers (ASME)
titleFascicular Elastin Modulates Recovery of Mechanical Properties Following Subfailure Repetitive Loading
typeJournal Paper
journal volume148
journal issue8
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4072061
journal fristpage31
journal lastpage45
page15
treeJournal of Biomechanical Engineering:;2026:;volume( 148 ):;issue:008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record