| contributor author | Zhou, Yingwu | |
| contributor author | Liu, Guifan | |
| contributor author | Zhao, Linlin | |
| contributor author | Hu, Biao | |
| contributor author | Liu, Ruibo | |
| contributor author | Huang, Xiaoxu | |
| contributor author | Zhu, Zhongfeng | |
| date accessioned | 2026-08-20T21:30:42Z | |
| date available | 2026-08-20T21:30:42Z | |
| date copyright | 2026/03/16 | |
| date issued | 2026 | |
| identifier other | JCCOF2.CCENG-5425.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4314574 | |
| description abstract | Abstract Impressed current cathodic protection (ICCP) is an effective method for mitigating
steel corrosion. Carbon fiber–reinforced polymer (CFRP) bars offer dual functionality
in ICCP-integrated concrete structures, serving as both anodes and concrete ... | |
| publisher | American Society of Civil Engineers | |
| title | Multiscale Insights into the Electrochemical and Mechanical Performance of CFRP Bars in a Real Concrete Environment under Anodic Polarization | |
| type | Journal Article | |
| journal volume | 30 | |
| journal issue | 3 | |
| journal title | Journal of Composites for Construction | |
| identifier doi | 10.1061/JCCOF2.CCENG-5425 | |
| journal fristpage | 04026013-1 | |
| journal lastpage | 04026013-20 | |
| page | 20 | |
| tree | Journal of Composites for Construction:;2026:;Volume ( 030 ):;issue: 003 | |
| contenttype | Fulltext | |