Show simple item record

contributor authorHari Narayana, Chandragiri
contributor authorNaik, Anusha
contributor authorNaik, Bishal
contributor authorMadhavan, Mahendrakumar Mathialagu
date accessioned2026-08-20T12:20:31Z
date available2026-08-20T12:20:31Z
date copyright2025/10/25
date issued2026
identifier otherJSENDH.STENG-14720.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4313380
description abstractAbstractThis research examines the pull-through failure behavior of cold-formed steel (CFS) C-shaped purlin-to-rafter connections using a cleat angle. A total of 72 tests were performed to evaluate the influence of cross-sectional parameters, including ...The left section shows C-shaped purlins connected to rafters via cleat angles, supporting the roof sheeting subjected to wind uplift forces indicated by upward arrows. The right section presents a test setup simulating wind uplift with a vertical loading ...Practical ApplicationsUsing a cleat angle to connect the purlin to the rafter provides significant advantages over direct screw connections of the purlin to the rafter. The advantages include lesser impact of the connection failure at high speed winds ...
publisherAmerican Society of Civil Engineers
titleCleat Angle Behavior in C-Shaped Purlin-to-Rafter Connections: Experimental Study and Design Considerations
typeJournal Article
journal volume152
journal issue1
journal titleJournal of Structural Engineering
identifier doi10.1061/JSENDH.STENG-14720
journal fristpage04025227-1
journal lastpage04025227-19
page19
treeJournal of Structural Engineering:;2026:;Volume ( 152 ):;issue: 001
contenttypeFulltext