description abstractAbstractDirect current (DC) traction systems such as a subway can cause time-resolved stray current interference in adjacent gas pipelines, leading to serious corrosion risk. It is important to evaluate risk according to the field test. In this paper, a ...Practical ApplicationsThis study proposes a corrosion risk assessment method that provides intuitive and reliable decision support for underground pipeline maintenance. Taking a natural gas pipeline along a metro line as an example, long-term monitoring ...
publisherAmerican Society of Civil Engineers
titleCorrosion Risk Assessment of Steel Gas Pipelines under Dynamic DC Interference according to In Situ Measurements
typeJournal Article
journal volume17
journal issue2
journal titleJournal of Pipeline Systems Engineering and Practice
identifier doi10.1061/JPSEA2.PSENG-1908
journal fristpage04026008-1
journal lastpage04026008-10
page10
treeJournal of Pipeline Systems Engineering and Practice:;2026:;Volume ( 017 ):;issue: 002