Show simple item record

contributor authorMahmood Chavoshan
contributor authorAhmadali Fallah
contributor authorAlireza Mirjalili
contributor authorMohammad Yekrangnia
date accessioned2024-12-24T10:11:57Z
date available2024-12-24T10:11:57Z
date copyright11/1/2024 12:00:00 AM
date issued2024
identifier otherPPSCFX.SCENG-1497.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4298474
description abstractThis paper reports a comprehensive study on the performance of the in-plane behavior of masonry walls. The use of wire rope and neoprene as a method for reinforcing existing masonry walls is proposed in this paper. The performances of the five walls with and without reinforcement were evaluated using experimental tests and numerical models. The first specimen was an unreinforced masonry wall (witness wall), which was tested under simultaneous cyclic and vertical loading. This wall was modeled using a simplified micro-modeling approach in the standard finite element software, Abaqus. A finite element (FE) study verified the experimental results to predict the in-plane behavior of masonry walls. Furthermore, to investigate the in-plane behavior of nonload-bearing walls in masonry structures, another sample with dimensions and a lateral loading protocol similar to the first sample was modeled by removing the vertical load. After a comprehensive understanding of the failure modes and damage mechanisms, the unreinforced load-bearing wall was strengthened using steel cables and neoprene in a cross-diagonal reinforcement pattern, whereas the unreinforced nonload-bearing wall was strengthened using steel cables and neoprene in a vertical pattern. The details of the modeling and wall construction, test setup, testing procedure, and results are described in detail in this study. The results indicated that the energy absorption capacity of the unreinforced walls was extremely low, and the effects of narrowing and asymmetry in the hysteresis curve were observed. The proposed retrofitting system increased the lateral load capacity, initial stiffness, deformation capacity (reducing the residual deformation), and energy dissipation capacity and created a self-centering response in the wall.
publisherAmerican Society of Civil Engineers
titleIn-Plane Seismic Strengthening of Brick Masonry Wall Using Wire Rope and Neoprene
typeJournal Article
journal volume29
journal issue4
journal titlePractice Periodical on Structural Design and Construction
identifier doi10.1061/PPSCFX.SCENG-1497
journal fristpage04024050-1
journal lastpage04024050-18
page18
treePractice Periodical on Structural Design and Construction:;2024:;Volume ( 029 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record