Show simple item record

contributor authorXinyao Xie
contributor authorZi-Xiong Guo
contributor authorSyed Humayun Basha
date accessioned2024-04-27T22:29:46Z
date available2024-04-27T22:29:46Z
date issued2024/05/01
identifier other10.1061-JSENDH.STENG-12626.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296789
description abstractThe present research aimed at investigating the out-of-plane (OOP) behavior of autoclaved aerated concrete (AAC) block masonry to further advance their application as structural infills considering different parameters (slenderness ratios, central window opening, and loading conditions) using a noncontact optical full-field strain measuring method. The fundamental behavior of AAC blocks and masonry assemblages were also assessed under different loads (compression, shear, and flexure) and verified with the design requirements. The development of arch-resisting mechanisms, OOP deformation profiles, cracking patterns, and damage mechanisms were assessed. Comprehensive comparative analysis was conducted to examine the OOP behavior of AAC block infilled frames with similarly constructed solid clay brick masonry infills. Further, an effort was made to review the requirements of the available design provisions and empirical models to envisage the OOP load and deformation capacities of AAC block masonry infills. The experimental investigation determined that lower slenderness ratio (15.1) specimens attained higher OOP load-bearing capacity (>3.5 times) and energy consumption (>2.1 times) compared with slender specimens (30.2). The presence of a window opening (11.3% area ratio) and repeated loading did not reveal significant reductions in OOP load (<15%) and deformation (0.83–0.94 times) capacities compared with the monotonic loading counterpart. The OOP arch-resisting mechanism vanished (capacity dropped to 20%–40% peak), and the failure was sudden due to the disintegration of the cross section and OOP fall-out of damaged components, demonstrating the OOP vulnerability of AAC infill. Crack widths and OOP deformation after vertical splitting cracks formation were precisely apprehended using the full-field strain measuring digital image correlation technique.
publisherASCE
titleOut-of-Plane Performance of Lightweight AAC Infills within RC Frames Using Noncontact Full-Field Strain Measurement Technique
typeJournal Article
journal volume150
journal issue5
journal titleJournal of Structural Engineering
identifier doi10.1061/JSENDH.STENG-12626
journal fristpage04024043-1
journal lastpage04024043-19
page19
treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record