Show simple item record

contributor authorMehta
contributor authorJason N.;Morales
contributor authorBrianna E.;Hsu
contributor authorFang-Chi;Rossmeisl
contributor authorJohn H.;Rylander
contributor authorChristopher G.
date accessioned2022-08-18T12:54:31Z
date available2022-08-18T12:54:31Z
date copyright6/16/2022 12:00:00 AM
date issued2022
identifier issn0148-0731
identifier otherbio_144_11_111003.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4287078
description abstractConvection-enhanced delivery (CED) has been extensively studied for drug delivery to the brain due to its inherent ability to bypass the blood-brain barrier. Unfortunately, CED has also been shown to inadequately distribute therapeutic agents over a large enough targeted tissue volume to be clinically beneficial. In this study, we explore the use of constant pressure infusions in addition to controlled catheter movement as a means to increase volume dispersed (Vd) in an agarose gel brain tissue phantom. Constant flow rate and constant pressure infusions were conducted with a stationary catheter, a catheter retracting at a rate of 0.25 mm/min, and a catheter retracting at a rate of 0.5 mm/min. The 0.25 mm/min and 0.5 mm/min retracting constant pressure catheters resulted in significantly larger Vd compared to any other group, with a 105% increase and a 155% increase compared to the stationary constant flow rate catheter, respectively. These same constant pressure retracting infusions resulted in a 42% and 45% increase in Vd compared to their constant flow rate counterparts. Using constant pressure infusions coupled with controlled catheter movement appears to have a beneficial effect on Vd in agarose gel. Furthermore, constant pressure infusions reveal the fundamental limitation of flow-driven infusions in both controlled catheter movement protocols as well as in stationary protocols where maximum infusion volume can never be reliably obtained.
publisherThe American Society of Mechanical Engineers (ASME)
titleConstant Pressure Convection-Enhanced Delivery Increases Volume Dispersed With Catheter Movement in Agarose
typeJournal Paper
journal volume144
journal issue11
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4054729
journal fristpage111003-1
journal lastpage111003-8
page8
treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record