Show simple item record

contributor authorMohedas
contributor authorIbrahim;Bell
contributor authorCarrie;Bekele
contributor authorDelayehu;Jiang
contributor authorKevin;Soyars
contributor authorCaroline;Walsh
contributor authorMadeleine;Sienko
contributor authorKathleen H.
date accessioned2022-08-18T12:51:37Z
date available2022-08-18T12:51:37Z
date copyright6/16/2022 12:00:00 AM
date issued2022
identifier issn1932-6181
identifier othermed_016_04_044501.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286986
description abstractWorldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult-to-access settings in low- and middle-income countries. Further, the availability and delivery of effective contraception in rural areas are limited by the lack of trained healthcare providers required to administer long-acting reversible contraceptives. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to ensure appropriate and consistent subdermal administration. Cadaver testing and ultrasound depth measurements were used to evaluate the performance of the SubQ Assist. Implant insertion outcomes between the SubQ Assist operated by a trained clinician and the conventional freehand insertion method by a trained clinician were compared. Cadaver testing and ultrasound depth measurements demonstrated that the SubQ Assist resulted in implant insertions that were statistically equivalent to implants inserted using the freehand insertion method. Additionally, the results showed that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrated that the SubQ Assist can consistently insert implants at an appropriate depth. Pending clinical testing, the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants from providers with advanced skills to minimally trained providers in order to expand access in rural areas.
publisherThe American Society of Mechanical Engineers (ASME)
titlePreclinical Evaluation of a Task-Shifting Contraceptive Implant Insertion Device for Use in Low- and Middle-Income Countries
typeJournal Paper
journal volume16
journal issue4
journal titleJournal of Medical Devices
identifier doi10.1115/1.4054684
journal fristpage44501-1
journal lastpage44501-6
page6
treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record