Show simple item record

contributor authorLi, Yu
contributor authorFei, Han
contributor authorWang, Jun
contributor authorLi, Ting
contributor authorFeng, Yihui
contributor authorHuan, Yong
date accessioned2022-05-08T09:23:42Z
date available2022-05-08T09:23:42Z
date copyright12/17/2021 12:00:00 AM
date issued2021
identifier issn0148-0731
identifier otherbio_144_04_041009.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285085
description abstractStress shielding is an important factor in the internal fixation of a fracture. To explore the regularity of stress shielding in internal fixation, a simplified model of a comminuted femoral shaft fracture bridged by a locking plate was established and finite element analysis was performed to analyze the load distribution between the plate and femur from the proximal end of the femur to the fracture line and investigate the stress shielding degree of the plate on the bone. The stress, deformation, and axial compressive force distribution of four internal fixation schemes under compression were obtained, and the stress shielding degrees on each section was calculated. To compare the regularity of stress shielding and flow distribution, the relationship between the compressive force increment and stress shielding degree was established. The normalized curves of compressive force increment with the plate section position were compared with the flow distribution in a Z-type manifold, a parallel pipe system similar to an internal fixation system in structure and working characteristics. For quantitative comparison, the similarity between normalized curves of the compressive force increment and simulated flow distribution was calculated. The regularity of load distribution along the section position of the plate was similar to the flow distribution in the Z-type manifold. Therefore, the flow distribution pattern of the Z-type manifold can be used to characterize the regularity of load distribution in internal fixation. This study provided a new method to characterize the stress shielding degree of a locking plate on bone.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Regularity of Stress Shielding in Internal Fixation Characterized by Hydromechanics
typeJournal Paper
journal volume144
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4052884
journal fristpage41009-1
journal lastpage41009-7
page7
treeJournal of Biomechanical Engineering:;2021:;volume( 144 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record