Show simple item record

DOI: 10.1115/1.4041273]

contributor authorNannarone, Alessandro
contributor authorKlein, Sikke A.
date accessioned2022-05-08T09:20:13Z
date available2022-05-08T09:20:13Z
date copyright2/10/2022 12:00:00 AM
date issued2022
identifier issn0742-4795
identifier othergtp_144_04_047001.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285010
description abstractThe following two equations contain corrections, respectively, for Eqs. (16) and (17): (16)σr,j−αE(1−v)(12Tave−12 ∑j=0jTjVj∑j=0jVj)=0(17)σc,j−αE(1−v)(12Tave+12 ∑j=0jTjVj∑j=0jVj−Tj)=0
publisherThe American Society of Mechanical Engineers (ASME)
titleErratum: “Start-Up Optimization of a CCGT Power Station Using Model-Based Gas Turbine Control” [ASME J. Eng. Gas Turbines Power, 2019, 141(4), p. 041018
titleDOI: 10.1115/1.4041273]
typeJournal Paper
journal volume144
journal issue4
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4053058
journal fristpage47001-1
journal lastpage47001-1
page1
treeJournal of Engineering for Gas Turbines and Power:;2022:;volume( 144 ):;issue: 004