Show simple item record

contributor authorGebai, Sarah
contributor authorCumunel, Gwendal
contributor authorHammoud, Mohammad
contributor authorForet, Gilles
contributor authorRoze, Emmanuel
contributor authorHainque, Elodie
date accessioned2022-05-08T08:37:50Z
date available2022-05-08T08:37:50Z
date copyright3/30/2022 12:00:00 AM
date issued2022
identifier issn0148-0731
identifier otherbio_144_09_091003.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284148
description abstractTremor is a semirhythmic oscillatory movement of a body part caused by alternating simultaneous contractions of an antagonistic muscle group. Medical and surgical treatments used to reduce the symptoms of involuntary tremor can cause negative side effects. This study examined the ability of passive vibration absorbers in reducing the amplitude of postural tremor (PT). Inertial measurement unit (IMU) was used to record PT signals at the forearm and hand of a patient. IMU signal was used to excite an upper limb modeled to represent the flexion–extension vibrational motion at the joints. Equations of motion were solved numerically to obtain a response that fits the measured tremor signal. Passive tuned mass damper (TMD) was modeled as a cantilever beam and a screw placed along its length, at a position reflecting its operational frequency. Natural frequency of the TMD was derived for different mass positions and validated numerically and experimentally. Modal damping ratio of the TMD, for each mass position, was also estimated. Mass position and damping coefficient of the TMD were optimized depending on the minimization in the power spectral density (PSD) of angular displacement amplitude at the wrist joint. Optimized three-TMD system of 28.64 g total effective mass with the estimated modal damping ratio reduced 83.1% of the PSD of the angular displacement amplitude. This study showed the performance ability of a lightweight passive absorber in controlling the involuntary tremor of a system excited by the measured tremor signal of a patient.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign and Simulation of a Passive Absorber to Reduce Measured Postural Tremor Signal
typeJournal Paper
journal volume144
journal issue9
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4053998
journal fristpage91003-1
journal lastpage91003-13
page13
treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record