Show simple item record

contributor authorBons, Zachary
contributor authorDickinson, Taylor
contributor authorClark, Ryan
contributor authorBeardsley, Kari
contributor authorCharles, Steven K.
date accessioned2022-05-08T08:19:03Z
date available2022-05-08T08:19:03Z
date copyright2/18/2022 12:00:00 AM
date issued2022
identifier issn0148-0731
identifier otherbio_144_07_071007.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283793
description abstractMost motion capture measurements suffer from soft-tissue artifacts (STA). Especially affected are rotations about the long axis of a limb segment, such as humeral internal-external rotation (HIER) and forearm pronation-supination (FPS). Unfortunately, most existing methods to compensate for STA were designed for optoelectronic motion capture systems. We present and evaluate an STA compensation method that (1) compensates for STA in HIER and/or FPS, (2) is developed specifically for electromagnetic motion capture systems, and (3) does not require additional calibration or data. To compensate for STA, calculation of HIER angles relies on forearm orientation, and calculation of FPS angles rely on hand orientation. To test this approach, we recorded whole-arm movement data from eight subjects and compared their joint angle trajectories calculated according to progressive levels of STA compensation. Compensated HIER and FPS angles were significantly larger than uncompensated angles. Although the effect of STA compensation on other joint angles (besides HIER and FPS) was usually modest, significant effects were seen in certain degrees-of-freedom under some conditions. Overall, the method functioned as intended during most of the range of motion of the upper limb, but it becomes unstable in extreme elbow extension and extreme wrist flexion–extension. Specifically, this method is not recommended for movements within 20 deg of full elbow extension, full wrist flexion, or full wrist extension. Since this method does not require additional calibration of data, it can be applied retroactively to data collected without the intent to compensate for STA.
publisherThe American Society of Mechanical Engineers (ASME)
titleCompensating for Soft-Tissue Artifact Using the Orientation of Distal Limb Segments During Electromagnetic Motion Capture of the Upper Limb
typeJournal Paper
journal volume144
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4053366
journal fristpage71007-1
journal lastpage71007-14
page14
treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record