Show simple item record

contributor authorSan Andrés, Luis
contributor authorToner, Jonathan
contributor authorAlcantar, Andy
date accessioned2022-02-06T05:31:49Z
date available2022-02-06T05:31:49Z
date copyright9/30/2021 12:00:00 AM
date issued2021
identifier issn0742-4795
identifier othergtp_143_11_111012.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278223
description abstractOperation of tilting pad journal bearings (TPJBs) with a reduced flow decreases pumping costs and oil sump storage. A low supplied oil flow improves system energy efficiency by reducing drag power losses, albeit the temperature rise in both the bearing pads and the lubricating oil become a concern. This paper presents measurements of the static and dynamic load performance of a flooded ends TPJB lubricated with an ISO VG 46 oil supplied at 60 °C, and with a flow rate ranging from 150% to just ∼5% of a nominal supply condition. The flow range covers both over-flooded and starved flow conditions. The test bearing is a four-pad, 102 mm diameter, center pivot, with single orifice feeds, and configured with end seals to flood the bearing housing. The experiments include operation at two shaft speeds = 6 krpm and 12 krpm (= 64 m/s surface speed) and under three specific loads = 0.345 MPa, 1.03 MPa, and 2.07 MPa applied in between pads (LBP). The measurements show the bearing drag power loss decreases by nearly 20% when the flow rate drops to 50% of nominal. However, halving the flow produces a raise in pad subsurface temperatures, ∼7 °C for operation at 12 krpm. Flow reduction below 50% does result in even more substantial power savings; however, it also produces too hot pad temperatures that approach 130 °C, a known limit for Babbitt material safe operation. The bearing static eccentricity (e) and direct stiffnesses Kxx < Kyy (load direction) do not show a significant dependency on the supplied flow, either above or below the nominal condition. A minor stiffness hardening does occur for very low flow conditions, 5% or so of nominal. Damping coefficients (Cxx ∼ Cyy) decrease by ∼30% as the flow rate decreases from 150% to just a few % of the nominal flow. The experimental results are first to quantify the operation of a TPJB supplied with minute amounts of lubricant flow. A test with a very low flow rate at ∼2% of nominal and under a light load produced the emergence of a broadband subsynchronous vibration (SSV) frequency, albeit with a very small amplitude.
publisherThe American Society of Mechanical Engineers (ASME)
titleMeasurements to Quantify the Effect of a Reduced Flow Rate on the Performance of a Tilting Pad Journal Bearing With Flooded Ends
typeJournal Paper
journal volume143
journal issue11
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4052268
journal fristpage0111012-1
journal lastpage0111012-12
page12
treeJournal of Engineering for Gas Turbines and Power:;2021:;volume( 143 ):;issue: 011
contenttypeFulltext