Show simple item record

contributor authorEl Jirari, I.
contributor authorEl Baroudi, A.
contributor authorAmmar, A.
date accessioned2022-02-05T22:39:55Z
date available2022-02-05T22:39:55Z
date copyright3/8/2021 12:00:00 AM
date issued2021
identifier issn0148-0731
identifier otherbio_143_05_051009.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277936
description abstractThe study of artificial microparticles (capsules and vesicles) has gained a growing interest with the emergence of bio-engineering. One of their promoting applications is their use as therapeutic vectors for drug delivery, when capsules and vesicles release their capacity in a targeted environment. The dynamic behavior of capsules and vesicles in confined or unbounded flows was widely studied in the literature and their mechanical response was truthfully described using constitutive laws with good agreement with experiences. However, in a context of biological application, to our knowledge, none of published studies investigating the mechanical response of deformable microparticle took into account the real physiological conditions: the rheological properties of blood such as carrying fluid and the mechanical properties of blood vessels. In this paper, we consider a hyperelastic microparticle suspended in human arteriole. We investigate the deformation of the microparticle resulting from its interaction with blood flow and the arteriolar wall using various capillary numbers and respecting physiological properties of blood and arterial wall. The influence of the blood viscosity model (Newtonian versus shear thinning) is investigated and a comparison with a rigid microchannel and a muscle-embedded arteriole is carried out. The fluid structure interaction (FSI) problem is solved using arbitrary Lagrangian Eulerian (ALE) method. Our simulations have revealed that the arteriolar wall distensibility deeply influences both the deformation and velocity of the microparticle: the deformation strongly increases while the velocity decreases in comparison to an infinitely rigid wall. In the context of therapeutic procedure of targeted drug-delivery, a particular attention should be addressed to these observations, in particular for their implication in the burst mechanism.
publisherThe American Society of Mechanical Engineers (ASME)
titleNumerical Investigation of the Dynamical Behavior of a Fluid-Filled Microparticle Suspended in Human Arteriole
typeJournal Paper
journal volume143
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4049955
journal fristpage051009-1
journal lastpage051009-10
page10
treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record