Show simple item record

contributor authorAlexander Max, Baker
contributor authorHostetler, Zach
contributor authorVavalle, Nicholas
contributor authorArmiger, Robert
contributor authorCoates, Randolph
contributor authorGayzik, Francis
date accessioned2022-02-05T22:18:01Z
date available2022-02-05T22:18:01Z
date copyright11/23/2020 12:00:00 AM
date issued2020
identifier issn0148-0731
identifier otherbio_143_01_014505.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277303
description abstractInjury due to underbody loading is increasingly relevant to the safety of the modern warfighter. To accurately evaluate injury risk in this loading modality, a biofidelic anthropomorphic test device (e.g., dummy) is required. Finite element model counterparts to the physical dummies are also useful tools in the evaluation of injury risk, but require validated constitutive material models used in the dummy. However, material model fitting can result in models that are over-fit: they match well with the data they were trained on, but do not extrapolate well to new loading scenarios. In this study, we used a hierarchical approach. Material models created from coupon-level tests were evaluated at the component level, and then verified using blinded component and whole body (WB) tests to establish a material model of the anthropomorphic test device (ATD) neck that was not over-fit. Additionally, a combined metric is introduced that incorporates the well-known correlation analysis (CORA) score with peak characteristics to holistically evaluate the material model performance. A Bergstrom Boyce material model fit to one loop of combined compression and tension experimental data performed the best within the training datasets. Its combined metric scores were 2.51 and 2.18 (max score of 3) in a constrained neck and head neck setup, respectively. In the blinded evaluation including flexed, extended, and WB simulations, similar combined scores were observed with 2.44, 2.26, and 2.60, respectively. The agreement between the combined scores in the training and validation dataset indicated that model was not over-fit and can be extrapolated into untested, but similar loading scenarios.
publisherThe American Society of Mechanical Engineers (ASME)
titleHierarchical Validation Prevents Over-Fitting of the Neck Material Model for an Anthropomorphic Test Device Used in Underbody Blast Scenarios
typeJournal Paper
journal volume143
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4048706
journal fristpage014505-1
journal lastpage014505-11
page11
treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record