Show simple item record

contributor authorJennions, Ian
contributor authorAli, Fakhre
date accessioned2022-02-05T22:06:34Z
date available2022-02-05T22:06:34Z
date copyright4/2/2021 12:00:00 AM
date issued2021
identifier issn1948-5085
identifier othertsea_13_6_061015.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276930
description abstractThere are a number of systems on an aircraft working together, in harmony, to produce safe and trouble free flight. The environmental control system (ECS) is one of these systems, and its failure is a major contributor to unscheduled maintenance, particularly in older aircraft. The ECS is composed of several complex sub-systems and components, but at its heart is the passenger air conditioner (PACK). The PACK is prone to degradation, which can lead to the functional failure of the ECS. Often its degradation is masked by the overall ECS control system and this can, ultimately, result in the ECS shutting down and extensive maintenance being required. There are a number of critical fault modes associated with the PACK, and in this paper, those modes associated with the primary and secondary heat exchangers (SHX) are explored. A robust ECS simulation framework called Simscape ECS simulation under all conditions (SESAC) has previously been implemented, calibrated, and tested against data from healthy systems. Here the simulations are extended to cover degraded components in a representative Boeing 737-800 aircraft PACK model. Fault modes such as blockage and fouling are assessed for the primary and secondary heat exchangers of the PACK. Simulation results, in terms of temperature, pressure, and mass flow at various degradation severities, are presented and discussed. The results highlight the interdependency between the PACK components and the strong association between the primary and secondary heat exchangers performance. The reported simulation methodology and findings serve as a further step towards the goal of formulating a cost-effective ECS fault isolation and diagnostic solution.
publisherThe American Society of Mechanical Engineers (ASME)
titleAssessment of Heat Exchanger Degradation in a Boeing 737-800 Environmental Control System
typeJournal Paper
journal volume13
journal issue6
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4050324
journal fristpage061015-1
journal lastpage061015-13
page13
treeJournal of Thermal Science and Engineering Applications:;2021:;volume( 013 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record