Show simple item record

contributor authorSlama, Vaclav
contributor authorMrozek, Lukas
contributor authorTajc, Ladislav
contributor authorKlimko, Marek
contributor authorZitek, Pavel
date accessioned2022-02-05T21:52:20Z
date available2022-02-05T21:52:20Z
date copyright1/28/2021 12:00:00 AM
date issued2021
identifier issn2332-8983
identifier otherners_007_02_021401.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276496
description abstractA nuclear power plant also includes a secondary cycle, which main component is a steam turbine. The steam turbine processes the thermal and pressure energy of steam and converts it into mechanical energy. Reliable and safe operation of the steam turbine, thus of the entire block, is ensured by valves. The flow in a pair of control valves, where the steam flows through the valve chamber past the first valve to the second valve, is investigated in this paper. The experimentally determined flow characteristics of both valves were evaluated and results were generalized. The experiments were carried out in the Aerodynamic laboratory of the Institute of Thermomechanics of the Czech Academy of Sciences in Novy Knin where a wind tunnel for high speeds could be used. Data of the distribution of pressures in selected places were evaluated. The energy loss in the valves was compared with the loss in a separate diffuser with varying degrees of expansion. The influence of a valve strainer, which is a part situated upstream of the control valve cone, was also investigated. It was found out in which case and where there is a significant disturbance of the velocity flow field. The first valve in the chamber is more sensitive to pressure losses in contrast to the second valve which is comparable to an ideal design of the diffuser, which indicates that this part of the valve assembly is optimal. Regarding the strainers, it was found out that the strainer helps to balance the velocity ratios at the inlet to the valve which has a positive effect on reducing the total energy pressure loss. As a result, the loss in the first valve can be significantly reduced which helps to increase the efficiency of the whole turbine.
publisherThe American Society of Mechanical Engineers (ASME)
titleFlow Analysis in a Steam Turbine Control Valve With Through-Flow Valve Chamber
typeJournal Paper
journal volume7
journal issue2
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4049055
journal fristpage021401-1
journal lastpage021401-7
page7
treeJournal of Nuclear Engineering and Radiation Science:;2021:;volume( 007 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record