Show simple item record

contributor authorLi, Wuyang
contributor authorTrbojevic, Sara
contributor authorAlmarza, Alejandro J.
date accessioned2022-02-05T21:43:02Z
date available2022-02-05T21:43:02Z
date copyright3/12/2021 12:00:00 AM
date issued2021
identifier issn0148-0731
identifier otherbio_143_06_064501.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276201
description abstractThis technical brief explores the validity and trueness of fit for using the transverse isotropic biphasic and Kelvin models (first and second order generalized) for characterization of the viscoelastic tensile properties of the temporomandibular joint (TMJ) discs from pigs and goats at a strain rate of 10 mm/min. We performed incremental stress-relaxation tests from 0 to 12% strain, in 4% strain steps on pig TMJ disc samples. In addition, to compare the outcomes of these models between species, we also performed a single-step stress-relaxation test of 10% strain. The transverse isotropic biphasic model yielded reliable fits in reference to the least root mean squared error method only at low strain, while the Kelvin models yielded good fits at both low and high strain, with the second order generalized Kelvin model yielding the best fit. When comparing pig to goat TMJ disc in 10% strain stress-relaxation test, unlike the other two Kelvin models, the transverse isotropic model did not fit well for this larger step. In conclusion, the second order Kelvin model showed the best fits to the experimental data of both species. The transverse isotropic biphasic model did not fit well with the experimental data, although better at low strain, suggesting that the assumption of water flow only applies while uncrimping the collagen fibers. Thus, it is likely that the permeability from the biphasic model is not truly representative, and other biphasic models, such as the poroviscoelastic model, would likely yield more meaningful outputs and should be explored in future works.
publisherThe American Society of Mechanical Engineers (ASME)
titleComparison of the Trueness of Fits of the Biphasic Transverse Isotropic and Kelvin Models to the Tensile Behavior of Temporomandibular Joint Disc
typeJournal Paper
journal volume143
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4050033
journal fristpage064501-1
journal lastpage064501-7
page7
treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006
contenttypeFulltext