Show simple item record

contributor authorOzakin, Ahmet Numan
contributor authorYakut, Kenan
contributor authorKhalaji, Mansour Nasiri
date accessioned2022-02-04T22:54:13Z
date available2022-02-04T22:54:13Z
date copyright4/1/2020 12:00:00 AM
date issued2020
identifier issn0199-6231
identifier othersol_142_2_021010.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275671
description abstractIn this study, the performance of the combined system of photovoltaic-heat pump (PV/T) and effects of a newly designed evaporator on the performance of the combined system were numerically investigated. The coefficient of performance (COP) value of the heat pump and electrical efficiency of the photovoltaic system were determined considering the studies carried out at the same resource temperature. ansys Fluent software was used in the numerical analysis. According to the results, the electrical efficiency increased as expected. The maximum electrical efficiency obtained for photovoltaic system was 2.5% higher than those without cooling systems and the COP of the heat pump system was determined to be 4.75 at its maximum. The maximum exergetic efficiency of the combined system was calculated to be 55.5% at 6 m/s of refrigerant velocity.
publisherThe American Society of Mechanical Engineers (ASME)
titlePerformance Analysis of Photovoltaic-Heat Pump (PV/T) Combined Systems: A Comparative Numerical Study
typeJournal Paper
journal volume142
journal issue2
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4045313
journal fristpage021010-1
journal lastpage021010-10
page10
treeJournal of Solar Energy Engineering:;2020:;volume( 142 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record